Different lengths and mounting orientations. Varying configurations and features. With so many possible combinations, it can be difficult to choose the best power distribution unit (PDU) for your server rack. That’s why it’s important to evaluate your needs carefully before making a selection. We’ve put together this PDU buying guide to help you choose the optimal PDU for your rack.
PDUs can be mounted horizontally or vertically within the rack or enclosure.
Vertical PDUs are often preferred because they have more outlets and don’t take up equipment mounting space. However, horizontal PDUs can be valuable when in-row UPSs are used, the overall power load of the rack is low, or there is insufficient space to mount the PDU in the rear of the cabinet without blocking airflow.
While most office buildings in North America use single-phase power, large commercial buildings and data centers often have three-phase power (single vs. 3-phase power). The type of PDU you buy depends upon the type of power supplied to the racks and cabinets.
You also need to know how much power the equipment in the rack will consume. The maximum power consumption of each device should be printed on a placard on the back of the equipment or in the documentation. The power rating may be listed in volt-amps (VAs) or watts (W). Convert all to a common unit, add them up, and select a PDU with a higher power rating than the total.
In summary, the best PDU for your server rack will sufficiently accommodate your power supply (single or three-phase) as well as the power consumption of each device within the rack.
The PDU plug should match the input power source and the cord should be long enough to reach the power source. Power cords are limited to 15 feet according to UL requirements. Universal PDUs have seven-pin connectors that support multiple types of input power cables, enabling you to use one PDU model across the IT environment and adapt it to the available input power in each facility.
It’s also important to determine the number and type of outlets required for the equipment in the rack. IEC C13 outlets are the most common, but servers and other types of IT equipment may have different types of plugs. It’s a good idea to have a few extra outlets to accommodate future growth — as long as you don’t overload the PDU. Locking outlets prevent accidental disconnects. Check out our blog for more information about PDU power cord types.
Basic PDUs simply deliver power to the IT equipment in the rack or cabinet. However, there are also PDUs that provide valuable features that can simplify administration and power management. When choosing the best PDU for your server rack, consider the below configuration options:
With so many variables to consider, it can be tough to make a decision. Take a look at these 7 questions to ask before selecting a PDU to help guide you into the right configuration for your server rack and data center.
Enconnex offers a wide range of PDU configurations, features, and options, many of which are readily available for immediate shipping. Enconnex PDUs are manufactured to the highest standards and carry all major certifications, including UL, CE, IEC 62368-1, FCC, NEMKO, and UKCA.
Our team is here to help you select the right PDU not only for your server rack but for your unique use case and environment. Learn why Enconnex PDUs are trusted by some of the largest companies in the world for excellent quality, consistent performance, superb value, and quick delivery. Contact a PDU expert today.